• DocumentCode
    1143503
  • Title

    High sensitivity detectors for measurement of space potential fluctuations

  • Author

    Keating, L.M. ; Schoch, P.M. ; Crowley, T.P. ; Russell, W.G. ; Schatz, J.G., Jr.

  • Author_Institution
    Rensselaer Polytech. Inst., Troy, NY, USA
  • Volume
    22
  • Issue
    4
  • fYear
    1994
  • fDate
    8/1/1994 12:00:00 AM
  • Firstpage
    424
  • Lastpage
    429
  • Abstract
    A detection technique yielding an order of magnitude increase in the sensitivity of a Proca-Green type energy analyzer to beam energy fluctuations has been demonstrated. A sensitivity of <1 part in 10 6 is possible. The technique can be used to increase the sensitivity of a Heavy Ion Beam Probe (HIBP) to space potential fluctuations in a plasma. The increase in sensitivity is achieved by splitting the detected ion beam into 10 smaller beamlets and summing the signals produced by the beamlets. Experimental results from an ion beam test facility are presented along with the projected results if implemented on the 2 MeV HIBP on the TEXT-Upgrade tokamak
  • Keywords
    Tokamak devices; fluctuations; ion beams; plasma diagnostics; plasma probes; plasma toroidal confinement; sensitivity; space charge; Proca-Green type energy analyzer; TEXT-Upgrade tokamak; beam energy fluctuations; beamlets; detection technique; heavy ion beam probe; high sensitivity detectors; ion beam test facility; sensitivity; space potential fluctuations; splitting; Current measurement; Detectors; Electrostatic analysis; Energy measurement; Extraterrestrial measurements; Fluctuations; Geometry; Ion beams; Plasma measurements; Test facilities;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/27.310650
  • Filename
    310650