• DocumentCode
    1143927
  • Title

    Pulmonary Lobe Segmentation in CT Examinations Using Implicit Surface Fitting

  • Author

    Pu, Jiantao ; Zheng, Bin ; Leader, Joseph K. ; Fuhrman, Carl ; Knollmann, Friedrich ; Klym, Amy ; Gur, David

  • Author_Institution
    Dept. of Radiol., Univ. of Pittsburgh, Pittsburgh, PA, USA
  • Volume
    28
  • Issue
    12
  • fYear
    2009
  • Firstpage
    1986
  • Lastpage
    1996
  • Abstract
    Lobe identification in computed tomography (CT) examinations is often an important consideration during the diagnostic process as well as during treatment planning because of their relative independence of each other in terms of anatomy and function. In this paper, we present a new automated scheme for segmenting lung lobes depicted on 3-D CT examinations. The unique characteristic of this scheme is the representation of fissures in the form of implicit functions using radial basis functions (RBFs), capable of seamlessly interpolating ldquoholesrdquo in the detected fissures and smoothly extrapolating the fissure surfaces to the lung boundaries resulting in a ldquonaturalrdquo segmentation of lung lobes. A previously developed statistically based approach is used to detect pulmonary fissures and the constraint points for implicit surface fitting are selected from detected fissure surfaces in a greedy manner to improve fitting efficiency. In a preliminary assessment study, lobe segmentation results of 65 chest CT examinations, five of which were reconstructed with three section thicknesses of 0.625 mm, 1.25 mm, and 2.5 mm, were subjectively and independently evaluated by two experienced chest radiologists using a five category rating scale (i.e., excellent, good, fair, poor, and unacceptable). Thirty-three of 65 examinations (50.8%) with a section thickness of 0.625 mm were rated as either ldquoexcellentrdquo or ldquogoodrdquo by both radiologists and only one case (1.5%) was rated by both radiologists as ldquopoorrdquo or ldquounacceptable.rdquo Comparable performance was obtained with a slice thickness of 1.25 mm, but substantial performance deterioration occurred in examinations with a section thickness of 2.5 mm. The advantages of this scheme are its full automation, relative insensitivity to fissure completeness, and ease of implementation.
  • Keywords
    computerised tomography; diagnostic radiography; image reconstruction; image segmentation; medical image processing; radial basis function networks; CT examinations; computed tomography; image reconstruction; implicit surface fitting; pulmonary lobe segmentation; radial basis functions; radiology; Anatomy; Computed tomography; Diseases; Image segmentation; Lungs; Process planning; Radiology; Surface fitting; Surface reconstruction; Surface treatment; Computed tomography (CT); computer-aided diagnosis; lobe segmentation; radial basis function (RBF); Algorithms; Artificial Intelligence; Humans; Imaging, Three-Dimensional; Lung; Pattern Recognition, Automated; Pulmonary Disease, Chronic Obstructive; Radiographic Image Enhancement; Radiographic Image Interpretation, Computer-Assisted; Reproducibility of Results; Sensitivity and Specificity; Tomography, X-Ray Computed;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2009.2027117
  • Filename
    5170058