• DocumentCode
    1144175
  • Title

    On the imaging of hot spots using correlation radiometers and a circular aperture

  • Author

    Schaller, Gerd

  • Author_Institution
    Inst. fur Hochfrequenztech., Erlangen-Nurnberg Univ., West Germany
  • Volume
    37
  • Issue
    8
  • fYear
    1989
  • fDate
    8/1/1989 12:00:00 AM
  • Firstpage
    1210
  • Lastpage
    1216
  • Abstract
    Results of computer simulations are presented for a microwave correlation radiometer system that uses a circular synthetic aperture for imaging hot spots in homogeneous lossy tissue. The previously described system (see IEEE MTT-5 Int. Microwave Symp. Dig., p.155-6, 1988) combined with a reconstruction algorithm has the ability to reconstruct correctly the position and the power density ratios of point-shaped noise sources with spatial resolution that is nearly constant in all directions and all over the object plane. It is shown that inexactly known attenuation and phase constants of the tissue affect the reconstructions only slightly
  • Keywords
    digital simulation; microwave imaging; radiometry; attenuation constants; circular aperture; computer simulations; correlation radiometers; homogeneous lossy tissue; hot spots; phase constants; point-shaped noise sources; power density ratios; reconstruction algorithm; spatial resolution; Apertures; Attenuation; Biomedical imaging; Image reconstruction; Medical diagnostic imaging; Microwave imaging; Radiometers; Reconstruction algorithms; Spatial resolution; Temperature;
  • fLanguage
    English
  • Journal_Title
    Microwave Theory and Techniques, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9480
  • Type

    jour

  • DOI
    10.1109/22.31080
  • Filename
    31080