DocumentCode :
1144195
Title :
Development of high-power density, 4-kV pulse transformers for TWTA
Author :
Kim, S.C. ; Nam, S.H. ; Kim, D.H.
Author_Institution :
Pohang Univ. of Sci. & Technol., Kyungbuk, South Korea
Volume :
32
Issue :
5
fYear :
2004
Firstpage :
1873
Lastpage :
1878
Abstract :
Pulse transformers suitable for high-frequency and high-voltage operations in a traveling-wave tube amplifier (TWTA) had been designed, fabricated, and tested. Two transformers with different operation frequency of 100 and 80 kHz were designed, fabricated, and tested. The transformer with 100-kHz switching frequency had input and output voltages of 250 Vdc and -4.1 kV, respectively. Operating power was 3.06 kW. Achieved power density of the 100-kHz transformers was 22.26 W/cm3. The transformer with 80-kHz switching frequency had input and output voltages of 265 Vdc and -4.1 kV, respectively. Normal operating power of the transformer was 1.67 kW. Achieved power density of the 80-kHz transformer was 12.15 W/cm3. Three different winding arrangements for the 80-kHz transformer were tested and it was found that the one with a sandwiched primary between secondary windings had the best performance in electrical characteristics. It was possible to reduce the stray capacitance while maintaining low-leakage inductance with the best arrangement. Therefore, the self-resonant frequency was far separated from the operating frequency, and, thus, the new arrangement minimized the self-resonant current that is generally one of source for transformer temperature rise.
Keywords :
pulse transformers; pulsed power supplies; travelling wave amplifiers; windings; -4.1 kV; 1.67 kW; 100 kHz; 250 V; 265 V; 3.06 kW; 4 kV; 80 kHz; high-power density pulse transformers; low-leakage inductance; sandwiched primary; secondary windings; self-resonant frequency; stray capacitance; switching frequency; traveling-wave tube amplifier; Capacitance; High power amplifiers; Inductance; Magnetic separation; Power supplies; Pulse amplifiers; Pulse transformers; Pulsed power supplies; Switching frequency; Testing; High-power density; TWTA; pulse transformer; traveling-wave tube amplifier;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/TPS.2004.835953
Filename :
1347238
Link To Document :