DocumentCode
1145742
Title
Rate of Rise of Short Circuit Current of D-C Motors and Generators [includes discussion]
Author
AIEE Committee Report ; Darling, A.G. ; Linville, T.M.
Volume
71
Issue
1
fYear
1952
Abstract
This paper gives the maximum rate of rise of current on short circuit and inductance between main terminals for d-c machines for a wide range of size and ratings. It supplements a previous paper4 in which the maximum values of short circuit current were given. The paper also gives a summary of formulas for calculating transient performance of d-c machines and d-c power systems.
Keywords
Circuit testing; Inductance; Induction motors; Machine windings; Machinery; Power system analysis computing; Power system faults; Power system protection; Power system transients; Short circuit currents;
fLanguage
English
Journal_Title
Power Apparatus and Systems, Part III. Transactions of the American Institute of Electrical Engineers
Publisher
ieee
ISSN
0097-2460
Type
jour
DOI
10.1109/AIEEPAS.1952.4498477
Filename
4498477
Link To Document