DocumentCode :
1146913
Title :
Analysis of the voltage harmonic distortion at buses feeding office loads
Author :
Demoulias, Charis S. ; Goutzamanis, D. ; Gouramanis, K.
Author_Institution :
Dept. of Electr. & Comput. Eng., Aristotle Univ. of Thessaloniki, Thessaloniki, Greece
Volume :
3
Issue :
4
fYear :
2009
fDate :
7/1/2009 12:00:00 AM
Firstpage :
286
Lastpage :
301
Abstract :
The harmonic distortion of the phase-to-neutral voltage at low-voltage buses feeding office load is investigated for various cable configurations, lengths and cross-sections. The investigation is carried out with a software model that was validated with analytical expressions and measurements taken at a real installation. It is shown that the selection of a cable should be based not only on its ampacity and allowable voltage drop but also on its configuration, in order to avoid excessive voltage harmonic distortion. Configurations where the neutral conductor is part of a four-core cable lead to relatively small harmonic distortion, whereas cable configurations where the neutral conductor runs separately cause high-voltage harmonic distortion. In the latter case, the neutral conductor develops a significant voltage with respect to the ground. Increasing the cross-section of the neutral conductor, as the existing standards dictate, may prevent its overloading from zero-sequence harmonic currents but hardly improves the voltage harmonic distortion at the load bus.
Keywords :
conductors (electric); harmonic distortion; microcomputers; power cables; buses feeding office load; four-core cable; neutral conductor; phase-to-neutral voltage buses feeding office load; software model; voltage harmonic distortion;
fLanguage :
English
Journal_Title :
Science, Measurement & Technology, IET
Publisher :
iet
ISSN :
1751-8822
Type :
jour
DOI :
10.1049/iet-smt.2008.0069
Filename :
5173455
Link To Document :
بازگشت