DocumentCode :
1148544
Title :
Electrical strength of paper-oil insulation subjected to composite voltages
Author :
Mosinski, Franciszek ; Wodzinski, Jerzy ; Sikorski, Lukasz ; Ziencikiewicz, Jozef
Author_Institution :
High Voltage Dept., Lodz Tech. Univ., Poland
Volume :
1
Issue :
4
fYear :
1994
fDate :
8/1/1994 12:00:00 AM
Firstpage :
615
Lastpage :
623
Abstract :
The results of a composite voltage, ac with lightning impulse (LI) tests of a paper-oil insulation model are presented. It was demonstrated that the presence of the background ac voltage leads to a decrease in LI breakdown voltage. This is particularly conspicuous at opposite polarities. The dispersion of LI breakdown voltages decreases save for the case when the LI is superimposed on the opposite polarities. The dispersion of LI breakdown voltages decreases save for the case, when the LI is superimposed on the opposite polarity peak value of the ac sinusoid. In this critical case the combined breakdown voltage (ac+LI) may be even lower than the ac one
Keywords :
electric strength; impulse testing; insulating oils; insulation testing; life testing; paper; background ac voltage; breakdown voltages; composite voltages; electrical strength; lightning impulse; opposite polarity peak value; paper-oil insulation; Circuit testing; Control systems; Dielectrics and electrical insulation; Impulse testing; Insulation testing; Lightning; Oscilloscopes; Power transformer insulation; System testing; Voltage;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/94.311704