• DocumentCode
    1148790
  • Title

    Fault Detection on Multicell Converter Based on Output Voltage Frequency Analysis

  • Author

    Lezana, Pablo ; Aguilera, Ricardo ; Rodríguez, José

  • Author_Institution
    Dept. de Electr., Univ. Tec. Federico Santa Maria, Valparaiso
  • Volume
    56
  • Issue
    6
  • fYear
    2009
  • fDate
    6/1/2009 12:00:00 AM
  • Firstpage
    2275
  • Lastpage
    2283
  • Abstract
    Multilevel converters use a large amount of semiconductors, allowing the reconfigurate of the converter to work even on internal fault condition. This paper presents a method to detect faulty cells in a cascaded multicell converter requiring just one voltage measurement per output phase. The method is based on high-frequency harmonic analysis, using a dynamic prediction of their behavior, avoiding erroneous detection on transients while keeping the precision under real fault events. Once the faulty cell is detected, it can be bypassed allowing the converter to keep working according to previously reported techniques. Experimental results confirm accurate and fast fault detection, with a good rejection to normal operation transients.
  • Keywords
    fault diagnosis; harmonic analysis; power conversion harmonics; voltage measurement; faulty cell detection; high-frequency harmonic analysis; multicell converter; voltage frequency analysis; voltage measurement; Digital control; fault diagnosis; multilevel systems; power electronics;
  • fLanguage
    English
  • Journal_Title
    Industrial Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0046
  • Type

    jour

  • DOI
    10.1109/TIE.2009.2013845
  • Filename
    4776498