DocumentCode
1148851
Title
Dead-Time Elimination of PWM-Controlled Inverter/Converter Without Separate Power Sources for Current Polarity Detection Circuit
Author
Lin, Yong-Kai ; Lai, Yen-Shin
Author_Institution
Nat. Taipei Univ. of Technol., Taipei
Volume
56
Issue
6
fYear
2009
fDate
6/1/2009 12:00:00 AM
Firstpage
2121
Lastpage
2127
Abstract
This paper will present a dead-time elimination scheme for a pulsewidth-modulation (PWM)-controlled inverter/converter. The presented dead-time elimination scheme does not require separated power supplies for freewheeling-current detection of high- and low-side power devices. The presented scheme includes the freewheeling-current polarity detection circuit and the PWM control generator without dead time. It will be shown that the presented scheme eliminates the dead time of PWM control for inverter/converter and therefore dramatically improves output voltage loss and current distortion. Experimental results derived from a field-programmable-gate-array-based PWM-controlled inverter are shown to demonstrate the effectiveness.
Keywords
PWM invertors; PWM power convertors; field programmable gate arrays; PWM-controlled converter; PWM-controlled inverter; current distortion; current polarity detection circuit; dead-time elimination; field-programmable-gate-array; freewheeling-current detection; Dead-time elimination; pulsewidth modulation (PWM);
fLanguage
English
Journal_Title
Industrial Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0278-0046
Type
jour
DOI
10.1109/TIE.2009.2014305