  • Abstract
    In the above-named work (ibid., vol.7, p.877-8, (Dec. 1991)), H. Zhuang and Z. S. Roth point out that a particular solution can be simplified by using quaternions to represent rotations. While it is true that this approach gives rise to an algorithm more efficient than the one considered, the commenter argues that it is incorrect to claim that a unique solution for R/sub X/ exists if and only if the axes of rotation of R/sub A1/ and R/sub A2/ are nonzero (theorem 1 of the original work). A counterexample is presented to prove this point. In replying, Zhuang and Roth note the error in the original work and provide an analysis leading to the revision of their original theorem 1.<>
  • Keywords
    calibration; electric sensing devices; position control; robots; calibration; homogeneous transform equations; quaternions; unique solution; wrist-mounted robotic sensors; Calibration; Cameras; Computer vision; Equations; Fasteners; Motion analysis; Quaternions; Robot sensing systems; Robotics and automation; Transforms;