DocumentCode
1153559
Title
A New Method for Part-Winding Starting of Polyphase Motors [includes discussion]
Author
Alger, P.L. ; Agacinsky, Lorraine M.
Author_Institution
FELLOW AIEE, General Electric Company, Schenectady, N. Y.
Volume
74
Issue
3
fYear
1955
Abstract
Part-winding or "step-starting" of polyphase induction motors for holding down the initial starting current inrush is on the increase. The conventional scheme provides two half-current starting contactors, each with three poles. The motors have dual-voltage 9-lead windings, arranged in two independent Y\´s, separately connected to the two contactors. The two contactors are closed in sequence with a few seconds\´ delay between, giving about 60 per cent (%) current on the first step. The delay must be very short, because the accelerating torque on half-winding is usually low, the motor may be noisy, and the rate of heating is high.
Keywords
Acceleration; Contactors; DH-HEMTs; Delay; Differential equations; Equivalent circuits; Niobium; Steady-state; Voltage; Writing;
fLanguage
English
Journal_Title
Power Apparatus and Systems, Part III. Transactions of the American Institute of Electrical Engineers
Publisher
ieee
ISSN
0097-2460
Type
jour
DOI
10.1109/AIEEPAS.1955.4499251
Filename
4499251
Link To Document