DocumentCode :
1153559
Title :
A New Method for Part-Winding Starting of Polyphase Motors [includes discussion]
Author :
Alger, P.L. ; Agacinsky, Lorraine M.
Author_Institution :
FELLOW AIEE, General Electric Company, Schenectady, N. Y.
Volume :
74
Issue :
3
fYear :
1955
Abstract :
Part-winding or "step-starting" of polyphase induction motors for holding down the initial starting current inrush is on the increase. The conventional scheme provides two half-current starting contactors, each with three poles. The motors have dual-voltage 9-lead windings, arranged in two independent Y\´s, separately connected to the two contactors. The two contactors are closed in sequence with a few seconds\´ delay between, giving about 60 per cent (%) current on the first step. The delay must be very short, because the accelerating torque on half-winding is usually low, the motor may be noisy, and the rate of heating is high.
Keywords :
Acceleration; Contactors; DH-HEMTs; Delay; Differential equations; Equivalent circuits; Niobium; Steady-state; Voltage; Writing;