Title :
Calculation of Corona-Starting Voltage in Air-Solid Dielectric Systems [includes discussion]
Author_Institution :
MEMBER AIEE, Fort Wayne Laboratory of the General Electric Company, Fort Wayne, Ind.
Abstract :
A method is described for determining the corona-starting voltage in air-solid dielectric systems when the thickness and the dielectric constants are known. The method is derived by applying data from Paschen´s law to the theoretical distribution of a voltage potential between air and a solid insulation. Two procedures for verifying the method and a determination of the accuracy are described. The extent of error due to field distortion and other factors is discussed. Examples showing how the method may be applied practically for air-solid dielectric systems containing more than one solid dielectric and the expected accuracy are included.
Keywords :
Air gaps; Breakdown voltage; Capacitors; Corona; Dielectric constant; Dielectrics and electrical insulation; Electrodes; Equations; Solids; Sparks;
Journal_Title :
Power Apparatus and Systems, Part III. Transactions of the American Institute of Electrical Engineers
DOI :
10.1109/AIEEPAS.1956.4499294