DocumentCode
1155236
Title
The measurement of magnetic parameters in a stacked yoke
Author
Usak, Elemir ; Jancarik, Vladimir
Author_Institution
Dept. of Theor. and Appl. Electr. Eng., Slovak Tech. Univ., Bratislava
Volume
30
Issue
2
fYear
1994
fDate
3/1/1994 12:00:00 AM
Firstpage
1070
Lastpage
1071
Abstract
The measurement of magnetic parameters in a system of stacked laminations can be affected by two basic effects. The first of them is a systematic error of used measuring equipment. In this paper we would like to point out the second effect that can arise in a stacked magnetic circuit. This effect is the influence of so-called co-operative phenomenon on the resulting magnetic properties of the system, such as power losses or amplitude permeability, etc
Keywords
iron alloys; laminations; magnetic permeability measurement; power transformers; silicon alloys; transformer magnetic circuits; transformer testing; FeSi; FeSi steel; amplitude permeability; power losses; stacked laminations; stacked magnetic circuit; stacked yoke; Density measurement; Loss measurement; Magnetic circuits; Magnetic domain walls; Magnetic domains; Magnetic field measurement; Magnetic properties; Permeability measurement; Power measurement; Stacking;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.312497