DocumentCode
1156041
Title
A Semiautomatic Test for Measuring the Loss in Transformer Core Laminations
Author
Leonard, S.C. ; Tenbroeck, R.L.
Volume
76
Issue
3
fYear
1957
fDate
4/1/1957 12:00:00 AM
Firstpage
118
Lastpage
124
Abstract
A method of measuring the loss in a fully processed core lamination is presented, including a mathematical analysis of the measuring circuitry. A servo-type flux density control and computer circuit as well as a calibration circuit are described which allow rapid testing of core material under normal operating conditions. High-speed testing essential for quality control and statistical studies is provided.
Keywords
Assembly; Circuit testing; Consumer electronics; Core loss; Integrated circuit measurements; Lamination; Loss measurement; Power transformers; Steel; Transformer cores;
fLanguage
English
Journal_Title
Power Apparatus and Systems, Part III. Transactions of the American Institute of Electrical Engineers
Publisher
ieee
ISSN
0097-2460
Type
jour
DOI
10.1109/AIEEPAS.1957.4499514
Filename
4499514
Link To Document