DocumentCode
1157233
Title
A Dual Modality Gamma Camera Using
Scintillator
Author
Lee, Wonho ; Wehe, David K. ; Jeong, Manhee ; Barton, Paul ; Berry, James
Author_Institution
Radiologic Sci. Dept., Korea Univ., Seoul
Volume
56
Issue
1
fYear
2009
Firstpage
308
Lastpage
315
Abstract
Portable gamma-ray imaging devices capable of responding to a broad energy range while providing reasonable angular resolution and efficiency are useful in a number of applications, including environmental remediation and industrial surveys. Due to this, a dual radiation imaging system that combines the advantages of a multi-aperture mechanical collimator with electronic-collimation has been designed, built, and tested. The combination of these two disparate imaging modalities offers both efficiency and good angular resolution, and is unique since a single gamma ray can contribute information to both modalities simultaneously. The dual modality gamma camera (DMGC) combines a high-resolution uniformly redundant array (URA) coded aperture with a Compton scatter camera to provide a broader range of energy response suitable for a wider range of industrial applications. The LaCl3(Ce) in the first detector module has 22times22 voxels, each voxel having a dimension of 2times2times5 mm3. The LaCl3(Ce) in the second detector module has 6times6 voxels having dimensions of 4times4times10 mm3. Both scintillators are coupled to position-sensitive photomultiplier tubes (PSPMT). The front-end, peak detection and coincident circuits of the DMGC are custom-designed for simplicity and compactness. Point and simulated ring radiation sources at intermediate energies (356 and 662 keV) are measured for mechanical, electronic and dual collimation and the reconstructed images are compared. The results show that the combined dual collimation image, using the maximum likelihood method for image reconstruction, yields better images than either a mechanical or an electronic collimation image at intermediate energies.
Keywords
Compton effect; cameras; coincidence techniques; collimators; gamma-ray apparatus; gamma-ray detection; high energy physics instrumentation computing; maximum likelihood estimation; nuclear electronics; photomultipliers; position sensitive particle detectors; scintillation counters; solid scintillation detectors; Compton scatter camera; LaCl3(Ce) scintillator; angular resolution; coincident circuits; dual collimation image; dual modality gamma camera; dual radiation imaging system; electronic collimation image; electronic-collimation; front-end circuits; high-resolution uniformly redundant array; maximum likelihood method; multiaperture mechanical collimator; peak detection circuits; portable gamma-ray imaging devices; position-sensitive photomultiplier tubes; radiation sources; reconstructed images; Cameras; Collimators; Detectors; Electronic equipment testing; Energy resolution; Image reconstruction; Image resolution; Nuclear imaging; Radiation imaging; System testing; ${rm LaCl}_{3}({rm Ce})$ ; Compton camera; dual camera; hybrid camera; scintillator; uniformly redundant array (URA);
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.2008.2011051
Filename
4782176