Title :
Improved torque fidelity in harmonic drive sensors through the union of two existing strategies
Author :
Sensinger, Jonathon W. ; Weir, Richard F ff
Author_Institution :
Dept. of Biomed. Eng., Northwestern Univ., Evanston, IL
Abstract :
The torsional compliance of harmonic drives lends itself to torque sensing, but the elliptical wave generator in harmonic drives introduces a spatially dependent local torque ripple on the flexspline of harmonic drives. It is difficult to extract the applied torque signal from this local torque ripple if the applied torque is sensed at the flexspline of the harmonic drive. Previous methods have used spatially offset Wheatstone bridges or gain tuning to attenuate torque ripple. The authors have found that combining both of these techniques through a different wiring configuration can attenuate local torque ripple to plusmn0.5 Nmiddotm, a better ripple reduction than either method alone. This local ripple reduction is adequate for large-range torque applications, but is not adequate for precision torque applications
Keywords :
drives; torque control; elliptical wave generator; harmonic drive sensors; offset Wheatstone bridges; ripple reduction; torque control; torque fidelity; torque ripple; torsional compliance; Actuators; Biomedical engineering; Biomedical measurements; Bridge circuits; Gears; Shape; Spline; Teeth; Torque control; Torque measurement; Compliance; harmonic drive; ripple tuning; torque control;
Journal_Title :
Mechatronics, IEEE/ASME Transactions on
DOI :
10.1109/TMECH.2006.878540