DocumentCode
1157688
Title
Effects of slot closure and magnetic saturation on induction machine behavior
Author
Salon, S. ; Burow, D. ; DeBortoli, M. ; Slavik, C.
Author_Institution
Dept. of Electr. Power Eng., Rensselaer Polytech. Inst., Troy, NY, USA
Volume
30
Issue
5
fYear
1994
fDate
9/1/1994 12:00:00 AM
Firstpage
3697
Lastpage
3700
Abstract
Reduction of the permeance variations due to slot openings can be achieved through the use of closed or semi-closed slots or magnetic slot wedges. A complete transient finite element model analyses the effects of slot closure in an induction motor. The analysis of the air gap flux density and magnetic force waves determined by the finite element model reveals two effects of stator slot closure: (a) a reduction of those flux density and force waves generated by stator slotting, which was expected, and (b) an increase in the amplitude of the flux density and force waves originating from saturation
Keywords
asynchronous machines; finite element analysis; machine theory; magnetic flux; air gap flux density; induction machine behavior; magnetic force waves; magnetic saturation; magnetic slot wedge; semi-closed slots; slot closure; transient finite element model; Coils; Finite element methods; Induction machines; Induction motors; Magnetic analysis; Magnetic flux; Reactive power; Saturation magnetization; Stators; Voltage;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.312744
Filename
312744
Link To Document