DocumentCode :
1158270
Title :
Design of electrode array of inductance flowmeter
Author :
Xu, Lijun ; Han, Jun ; Wang, Ya
Author_Institution :
Sch. of Electr. Eng. & Autom., Tianjin Univ., Tianjn, China
Volume :
5
Issue :
5
fYear :
2005
Firstpage :
929
Lastpage :
933
Abstract :
Multielectrode inductance flowmeters were brought forward toward coping with the problem of flow regime dependence of traditional inductance flowmeters. Design of the electrode array is of great importance in construction of a multielectrode inductance flowmeter. The number of electrodes and electrode size are two primary parameters of the array. In this paper, the governing equation of the multielectrode inductance flowmeter was solved using a finite difference method. The chord measurement method was employed to analyze the influences of both parameters on the estimation of mean flow velocity. Based on the quantitative calculation of the influences of the two parameters on measurement error, criteria for the design of the electrode array were presented.
Keywords :
design; electrodes; finite difference methods; flowmeters; inductance; measurement errors; velocity measurement; chord measurement; electrode array design; finite difference method; mean flow velocity; measurement error; multielectrode inductance flowmeters; Automation; Biomedical measurements; Distortion measurement; Electrodes; Finite difference methods; Fluid flow measurement; Inductance; Magnetic field measurement; Measurement errors; Velocity measurement; Electrode array; finite difference method; flow velocity; inductance flowmeter; measurement error;
fLanguage :
English
Journal_Title :
Sensors Journal, IEEE
Publisher :
ieee
ISSN :
1530-437X
Type :
jour
DOI :
10.1109/JSEN.2005.854486
Filename :
1504751
Link To Document :
بازگشت