DocumentCode
1159362
Title
Interception Probability and Shielding Against Lightning
Author
Mikropoulos, Pantelis N. ; Tsovilis, Thomas E.
Author_Institution
Dept. of Electr. Energy, Aristotle Univ. of Thessaloniki, Thessaloniki
Volume
24
Issue
2
fYear
2009
fDate
4/1/2009 12:00:00 AM
Firstpage
863
Lastpage
873
Abstract
A comprehensive analysis on shielding against lightning is presented. For an air terminal, the design of its protection zone and collection volume is introduced on the basis of simple working relationships which take into account, besides lightning parameters and air terminal height, the interception probability and use as a reference the striking distance to earth surface. The analysis, based on lightning scale-model experimental results, includes a comparison with previously reported models and field data; a satisfactory agreement is found. Lightning incidence calculations have been performed on the basis of lightning interception probability; a close conformity between the actual and calculated number of lightning strikes exists. Both striking distance and interception radius and their statistical nature should be considered for an accurate description of lightning interception.
Keywords
lightning protection; probability; shielding; lightning incidence calculation; lightning interception probability; lightning protection system; lightning scale-model; Air gaps; attractive radius; electric breakdown; interception probability; lightning protection; striking distance;
fLanguage
English
Journal_Title
Power Delivery, IEEE Transactions on
Publisher
ieee
ISSN
0885-8977
Type
jour
DOI
10.1109/TPWRD.2008.2002979
Filename
4783088
Link To Document