DocumentCode :
1159891
Title :
Valve Point Loading of Turbines
Author :
Decker, Gerald L. ; Brooks, Aaron D.
Volume :
77
Issue :
3
fYear :
1958
fDate :
4/1/1958 12:00:00 AM
Firstpage :
481
Lastpage :
484
Abstract :
Paralleled turbines should be loaded at selected valve points to maximize the power generation per pound of steam in preference to equal incremental steam rate loading using smooth average curves. The fact that turbines should spend a major portion of their useful working life on valve points instead of in between them, poses a logical question for the turbine and equipment manufacturers. Can valves, valve gear, governors and automatic dispatching equipment be adapted or redesigned to better fit and achieve this more precise and efficient valve point loading system for paralleled turbines?
Keywords :
Costs; Fuels; Natural gas; Petroleum; Power demand; Power generation; Power generation economics; Temperature; Turbines; Valves;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, Part III. Transactions of the American Institute of Electrical Engineers
Publisher :
ieee
ISSN :
0097-2460
Type :
jour
DOI :
10.1109/AIEEPAS.1958.4499963
Filename :
4499963
Link To Document :
بازگشت