• DocumentCode
    1160047
  • Title

    Elimination of the Skin Effect Error in Heavy-Current Shunts

  • Author

    Malewski, Ryszard ; Nguyen, Chinh T. ; Feser, Kurt ; Tén-Cavallius, Nils Hyl

  • Author_Institution
    Institut de recherche d´´ Hyd ro-Québec
  • Issue
    3
  • fYear
    1981
  • fDate
    3/1/1981 12:00:00 AM
  • Firstpage
    1333
  • Lastpage
    1340
  • Abstract
    A mathematical analysis of the transient skin effect in tubular and flat conductors has led to the development of a theory of ideal heavy-current shunts immune to the measuring error caused by this effect. A general expression was derived for calculating a profile of the measuring circuit laid inside the shunt wall that would give a step response undistorted by the skin effect. A model of the new shunt ws examined with a current step; the recorded response followed the applied pulse form.
  • Keywords
    Circuit testing; Conductors; Current measurement; Delay; IEEE members; Power system transients; Skin effect; Thermal resistance; Time measurement; Transient analysis;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1981.316606
  • Filename
    4110734