DocumentCode
1161455
Title
Steam Turbine Overspeed Control and Behavior During System Disturbances
Author
Younkins, T.D. ; Johnson, L.H.
Author_Institution
Electric Utility Systems Engineering Dept. General Electric Co.
Issue
5
fYear
1981
fDate
5/1/1981 12:00:00 AM
Firstpage
2504
Lastpage
2511
Abstract
System disturbances involving partial load rejection may cause turbine overspeed control action. To provide information necessary to evaluate power plant transients during such disturbances, this tutorial paper reviews the typical normal overspeed control functions on GE reheat steam turbines with either Electro-Hydraulic Control or Mechanical-Hydraulic Control. Normal overspeed control is related to speed control and the overspeed trip. The characteristic behavior of normal overspeed control is shown for full load rejections and a representative partial load rejection. Enhancement of power plant partial load rejection capability by considering combined turbine-boiler dynamic behavior is discussed.
Keywords
Control systems; Error correction; Frequency control; Power generation; Power industry; Power system dynamics; Power system interconnection; Pressure control; Turbines; Velocity control;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1981.316778
Filename
4110896