Title :
Further Studies of the Accuracy of Clamp-on Transit-Time Ultrasonic Flowmeters for Liquids
Author :
Mahadeva, Dharshanie V. ; Baker, Roger C. ; Woodhouse, Jim
Author_Institution :
Dept. of Eng., Univ. of Cambridge, Cambridge
fDate :
5/1/2009 12:00:00 AM
Abstract :
The higher value of uncertainty in the flow measurement signal from transit-time clamp-on ultrasonic flowmeters (USFMs) compared with transit-time spool-piece USFMs is due to several factors, some of which have been considered in this paper. However, the main focus of this paper has been on the effect of separation distance between the transducers on the flowmeter output signal. The sources of experimental error that might affect the validity of the data obtained for the transducer separation are examined, and then, use of ray-tracing and finite-difference models is made to examine this relationship theoretically.
Keywords :
finite difference methods; flow measurement; flowmeters; ray tracing; ultrasonic measurement; ultrasonic transducers; clamp-on transit-time ultrasonic flowmeters; finite-difference model; flow measurement signal; ray-tracing model; transducers; transit-time spool-piece ultrasonic flowmeters; Clamp-on; flow measurement; flow measurement for liquids; flowmeter; ray model; ultrasonic;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
DOI :
10.1109/TIM.2009.2012954