• DocumentCode
    1166321
  • Title

    A standstill frequency response method for large salient pole synchronous machines

  • Author

    Bortoni, Ed.C. ; Jardini, José Antônio

  • Author_Institution
    Fed. Univ. of Itajuba, Brazil
  • Volume
    19
  • Issue
    4
  • fYear
    2004
  • Firstpage
    687
  • Lastpage
    691
  • Abstract
    In this article, a Standstill Frequency Response Test (SSFR) is proposed, with the aim of determining the direct and quadrature axis operational impedances for salient pole synchronous machines. The method is applied with the rotor at standstill in a given arbitrary position, thus avoiding the difficulties in rotor mechanical alignment and rendering it suitable for large salient pole synchronous machines of hydroelectric power plants.
  • Keywords
    frequency response; hydroelectric power stations; machine testing; rotors; synchronous machines; direct axis operational impedance; hydroelectric power plant; large salient pole synchronous machine; quadrature axis operational impedance; rotor mechanical alignment; standstill frequency response method; Equations; Finite element methods; Frequency response; Impedance; Neural networks; Parameter estimation; Power generation; Rotors; Synchronous machines; Testing; 65; Frequency response; parameter estimation; synchronous machines;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/TEC.2004.832047
  • Filename
    1359947