Title :
Early Detection of Excessive Coil Vibration in High-Voltage Rotating Electric Machines
Author :
Nagano, S. ; Tari, M. ; Nakano, M. ; Ito, K. ; Uto, Y.
Author_Institution :
Keihin Product Operations Toshiba Corporation
fDate :
6/1/1982 12:00:00 AM
Abstract :
A safe and effective method of measuring stator end-winding vibrations of rotating electrical machinery and a vibration monitor are described. The method adopted is to measure electromagnetic vibration of the end-winding generating high voltage during operation. Measurements are obtained by piezoelectric pickups attached to end-winding surfaces. This method is often applied to measure vibration at other points, but it is difficult to effectively and safely measure end-winding vibration in the presence of high voltage and large current.
Keywords :
Coils; Current measurement; Electric machines; Electric variables measurement; Electromagnetic measurements; Machinery; Rotation measurement; Stators; Vibration measurement; Voltage;
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
DOI :
10.1109/TPAS.1982.317204