Title :
Damping of resonances at energization of transformers serving large pulse-type loads
Author :
Miri, Amir M. ; Sihler, Christof
Author_Institution :
Inst. fur Elektroenergiesysteme und Hochspannungstechnik, Univ. Karlsruhe, Germany
Abstract :
The ASDEX Upgrade tokamak, an experimental device for nuclear fusion research, requires an electrical power up to a few hundred megavoltamperes for a time period of 10-15 s. The power and energy is provided by isolated networks based on flywheel generators. About 20 power transformers must be energized on a daily basis to get the pulsed power supply operational for plasma experiments. Nuisance interactions of transformer inrush currents with the protection system of the synchronous machines and capacitor banks used for reactive power compensation must be avoided. To investigate the effects of inrush transients in present and future configurations, measurements were performed and a simulation model based on an equivalent magnetic circuit representation of the transformer was derived. The paper describes the model, results of simulation and measurement, and shows which measures were taken to keep transients in the isolated network at an acceptable level.
Keywords :
Tokamak devices; compensation; electric current measurement; electric generators; flywheels; magnetic circuits; power transformers; reactive power; synchronous machines; ASDEX upgrade tokamak; flywheel generator; isolated network; magnetic circuit representation; nuclear fusion research; power transformer; pulsed power supply; reactive power compensation; synchronous machine; Circuit simulation; Damping; Fusion reactors; Plasma measurements; Pulse transformers; Pulsed power supplies; Resonance; Surge protection; Tokamaks; Variable speed drives; 65; Isolated network; magnetic equivalent circuit; reactive power compensation; resonances; transformer inrush currents; transient analysis;
Journal_Title :
Industry Applications, IEEE Transactions on
DOI :
10.1109/TIA.2004.836142