DocumentCode :
1167292
Title :
A Capacitance Bridge Method for Measuring Integrated Corona-Charge Transfer and Power Loss per Cycle
Author :
Dakin, T.W. ; Malinaric, P.J.
Volume :
79
Issue :
3
fYear :
1960
fDate :
4/1/1960 12:00:00 AM
Firstpage :
648
Lastpage :
652
Abstract :
A more sensitive and accurate circuit has been devised and tested for showing integrated corona charge transfer per cycle in insulation samples. The method can be used as a very accurate and more rapid quality-control measurement of degree of impregnation or residual voids in apparatus insulation. A rather precise measurement of the fraction of gas space to solid in insulation structures can be obtained from this technique. The estimate of internal voids obtained from this technique is believed to be more accurate than that obtained from highvoltage Schering bridge measurements, with which it can be correlated.
Keywords :
Bridge circuits; Capacitance measurement; Charge transfer; Circuit testing; Corona; Extraterrestrial measurements; Insulation testing; Integrated circuit measurements; Loss measurement; Power measurement;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, Part III. Transactions of the American Institute of Electrical Engineers
Publisher :
ieee
ISSN :
0097-2460
Type :
jour
DOI :
10.1109/AIEEPAS.1960.4500823
Filename :
4500823
Link To Document :
بازگشت