Title :
Mathematical Analysis of Inductor Alternators
fDate :
4/1/1960 12:00:00 AM
Abstract :
A mathematical analysis has been put forward to analyze a 3-phase inductor alternator. Although one particular type of inductor alternator within the frequency range of 400-800 cps (cycles per second) has been analyzed in this paper,1 with suitable modifications, this analysis can be extended to other type of inductor alternators. This analysis is based on the calculation of self and mutual inductances of the coils, and so is quite suitable to analyze the machine under transient conditions.
Keywords :
Alternators; Frequency; Inductors; Magnetic circuits; Mathematical analysis; Rotors; Stators; Steady-state; Teeth; Torque;
Journal_Title :
Power Apparatus and Systems, Part III. Transactions of the American Institute of Electrical Engineers
DOI :