• DocumentCode
    1167477
  • Title

    TACS enhancements for the electromagnetic transient program

  • Author

    Lasseter, R.H. ; Zhou, J.

  • Author_Institution
    Wisconsin Univ., Madison, WI, USA
  • Volume
    9
  • Issue
    2
  • fYear
    1994
  • fDate
    5/1/1994 12:00:00 AM
  • Firstpage
    736
  • Lastpage
    742
  • Abstract
    Transient analysis of control systems (TACS) of the electromagnetic transient program (EMTP) has been enhanced in many ways. There are major changes in methods of ordering components to minimize the introduction of time step and history term errors. Initialization algorithms have been greatly enhanced to allow multiple frequency initialization. An “IF THEN ELSE” control structure and the use of user written FORTRAN routines are among the important new features available to users of TACS
  • Keywords
    control system analysis computing; control systems; power system analysis computing; power system control; power system transients; EMTP; IF THEN ELSE control structure; electromagnetic transient program; history term errors; initialization algorithms; multiple frequency initialization; power system transients; time step errors; transient analysis of control systems; user written FORTRAN routines; Control system synthesis; Control systems; Delay effects; EMTP; Equations; Frequency; History; Power system transients; Transfer functions; Transient analysis;
  • fLanguage
    English
  • Journal_Title
    Power Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8950
  • Type

    jour

  • DOI
    10.1109/59.317667
  • Filename
    317667