Title :
Turbine-generator shaft oscillation monitoring with PCs
Author :
Dalpiaz, C. Paul
Author_Institution :
Utah Power & Light, Salt Lake City, UT, USA
fDate :
7/1/1989 12:00:00 AM
Abstract :
The use of a PC-based system to record the speed of the shaft on five of Utah Power & Light´s largest steam turbine-generator units is described. This quantity will be fed to special protective relays. The relays are designed to detect mechanical resonance with natural frequencies below 60 Hz, called subsynchronous resonance.<>
Keywords :
angular velocity measurement; computerised instrumentation; machine protection; microcomputer applications; steam turbines; turbogenerators; USA; computerised instrumentation; machine protection; mechanical resonance; protective relays; shaft oscillation monitoring; speed; steam turbine-generator; subsynchronous resonance; turbogenerators; Computerized monitoring; Frequency; HVDC transmission; Personal communication networks; Relays; Resonance; Shafts; Turbines; Velocity measurement; Wheels;
Journal_Title :
Computer Applications in Power, IEEE