• DocumentCode
    1170771
  • Title

    Incipient Fault Identification Through Neutral RF Monitoring of Large Rotating Machines

  • Author

    Timperley, James E.

  • Author_Institution
    American Electric Power Service Corporation
  • Issue
    3
  • fYear
    1983
  • fDate
    3/1/1983 12:00:00 AM
  • Firstpage
    693
  • Lastpage
    698
  • Abstract
    Electromagnetic interference, or EMI, monitoring at an operating machine´s neutral can detect many types of stator deterioration, as well as various design defects. Accurate, wide-band spectrum analysis may indicate a problem´s location, its severity and its rate of change. This method can be sensitive enough to detect potential faults long before an inservice failure occurs. The salient results of numerous tests conducted during 1980 and 1981 are presented.
  • Keywords
    Condition monitoring; Electromagnetic interference; Fault detection; Fault diagnosis; Radio frequency; Radiofrequency identification; Rotating machines; Stators; Testing; Wideband;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1983.318030
  • Filename
    4111985