DocumentCode
1171108
Title
Wind Tunnel Measurements of the Power Imparted to a Model of a Vibrating Conductor
Author
Rawlins, C.B.
Author_Institution
Alcoa Conductor Products Co.
Issue
4
fYear
1983
fDate
4/1/1983 12:00:00 AM
Firstpage
963
Lastpage
971
Abstract
Predicting the severity of aeolian vibration of overhead conductors requires knowledge of the damping in the span and of the power that the wind can supply to it. There is considerable dispersion in the published data on wind power input. New measurements were made, using a novel test arrangement, in an effort to develop more reliable information. The tests covered a broad range of wind speeds, above and below that at which power input is greatest, to lay a basis for development of methods for dealing with the effects of turbulence in natural winds. Correlation of the new results with previous data is reviewed in depth.
Keywords
Conductors; Damping; Frequency; Power measurement; Testing; Uncertainty; Vibration measurement; Wind energy; Wind forecasting; Wind speed;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1983.317810
Filename
4112022
Link To Document