DocumentCode
1171155
Title
A Practical Approach to Appliance Load Control Analysis: A Water Heater Case Study
Author
Lee, S.H. ; Wilkins, C.L.
Author_Institution
Carolina Power & Light Company
Issue
4
fYear
1983
fDate
4/1/1983 12:00:00 AM
Firstpage
1007
Lastpage
1013
Abstract
General modeling techniques are presented to provide utility companies with a tool for analyzing the test data collected from their own systems. It is shown that benefits from load management may be assessed in different ways depending upon the goals to be achieved. To illustrate the use of the models presented, the results of the North and South Carolina water heater load control experiments are presented.
Keywords
Data analysis; Environmental economics; Home appliances; Load flow control; Load management; Power generation economics; Shape control; System testing; Temperature control; Water heating;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1983.317816
Filename
4112028
Link To Document