• DocumentCode
    1171373
  • Title

    Voxel-guided morphometry ("VGM") and application to stroke

  • Author

    Schormann, Thorsten ; Kraemer, Matthias

  • Author_Institution
    Heinrich-Heine Univ., Dusseldorf, Germany
  • Volume
    22
  • Issue
    1
  • fYear
    2003
  • Firstpage
    62
  • Lastpage
    74
  • Abstract
    Monitoring of cerebral diseases associated with a change of morphology (e.g., stroke) requires unprecedented accuracy for quantification of its morphological progression for each voxel. The purpose of this paper is to provide a technique [voxel-guided morphometry (VGM)] to quantify macroscopic anatomical differences. VGM consists of four steps: 1) coarse linear alignment by the extended principle axes theory (ePAT) generalized to affine movements; 2) a cross-correlation-based technique using a matrix-norm for fine linear alignment; 3) the applied high-dimensional multiresolution full multigrid method determines the nonlinear deformations, thereby achieving a complete exploitation of information and effective processing. The method measures a gray-value-guided movement of each voxel from source to target. The resulting high-dimensional deformation field is further processed by 4) determination of volume alterations for each voxel. Furthermore, the effect of linear registration errors on final morphometric measurements is discussed and the conditions for a bijective correspondence of voxels assuming small alterations are derived. To illustrate the technique the changing morphology of different subjects suffering from cerebral infarction is presented by using commonly available T1-weighted magnetic resonance volumes. VGM visualizes that ischemic as well as remote regions are affected by stroke.
  • Keywords
    biomedical MRI; brain; diseases; image registration; image resolution; medical image processing; patient monitoring; MRI data sets; T/sub 1/-weighted magnetic resonance volumes; VGM; accuracy; affine movements; bijective correspondence; cerebral disease monitoring; cerebral infarction; changing morphology; coarse linear alignment; cross-correlation-based technique; effective processing; extended principle axes theory; final morphometric measurements; fine linear alignment; gray-value-guided movement; high-dimensional deformation field; high-dimensional multiresolution full multigrid method; ischemic regions; linear registration errors; macroscopic anatomical differences; matrix-norm; morphological progression; nonlinear deformations; quantification; remote regions; small alterations; stroke; volume alterations; voxel-guided morphometry; Diseases; Helium; Magnetic analysis; Magnetic field measurement; Magnetic resonance; Magnetic resonance imaging; Morphology; Motion measurement; Multigrid methods; Visualization; Algorithms; Brain; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Infarction, Middle Cerebral Artery; Magnetic Resonance Imaging; Motion; Nonlinear Dynamics; Phantoms, Imaging; Quality Control; Signal Processing, Computer-Assisted; Stroke; Subtraction Technique;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2002.806571
  • Filename
    1191360