Title :
Full Scale Forced Cooling Tests at Waltz Mill
Author :
Burghardt, R.R. ; Mathews, H.G. ; Pumuhagen, D.W. ; Engelhardt, J.S.
Author_Institution :
Westinghouse Electric Corp.
fDate :
7/1/1983 12:00:00 AM
Abstract :
A heavily-instrumented full-scale facility to evaluate the forced-cooling characteristics of HPOF pipe-type cable has been in operation at the EPRI Waltz Mill Cable Test Facility. This paper describes the important details of the system and presents selected results. Particular emphasis is placed on the degree of cable snaking that occurred and its effect on the pressure drop and heat transfer characteristics of the cable system.
Keywords :
Cable shielding; Cables; Cooling; Heat transfer; Instruments; Milling machines; Petroleum; Test facilities; Testing; Wires;
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
DOI :
10.1109/TPAS.1983.318201