DocumentCode
1172784
Title
A Facility to Produce Uniform Space Charge for Evaluating ION Measuring Instruments
Author
McKnight, R.H. ; Kotter, F.R.
Author_Institution
National Bureau of Standards
Issue
7
fYear
1983
fDate
7/1/1983 12:00:00 AM
Firstpage
2349
Lastpage
2356
Abstract
A low-speed wind tunnel containing space charge has been constructed and evaluated. The facility is used for testing the performance of ion counters and net space charge measuring devices. For different operating conditions, space charge densities in the test volume range from 2.5-5.7 x 10-8 C/m3 . The space charge density is spatially uniform within 5% over more than than 900) of the cross sectional area of the test volume, but decreases by approximately 20% between two positions separated by 1 m. Ion densities achieved in this system are comparable to those found near high-voltage dc transmission lines but are free from the accompanying large electric fields.
Keywords
Atmospheric measurements; Charge measurement; Current measurement; Density measurement; HVDC transmission; Instruments; Power transmission lines; Space charge; Testing; Transmission line measurements;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1983.318161
Filename
4112220
Link To Document