• DocumentCode
    1173177
  • Title

    An AC/DC converter with high power factor

  • Author

    Ochiai, Masashi ; Matsuo, Hirofumi

  • Author_Institution
    Digital Media Network Co., Toshiba Corp., Tokyo, Japan
  • Volume
    50
  • Issue
    2
  • fYear
    2003
  • fDate
    4/1/2003 12:00:00 AM
  • Firstpage
    356
  • Lastpage
    361
  • Abstract
    The television receiver often employs a capacitor-input-type rectifier. In this case, it is regulated as a class D piece of equipment. This paper presents a novel ringing-choke-converter-type switching regulator, which functions as an active filter. The proposed circuit features a simple circuit configuration and cost effectiveness. It achieves a high power factor of about 0.95 and reduces current harmonics (third, fifth, and seventh) in the AC input current to less than 40% of the limit value for class D. The voltage across the input smoothing capacitor does not show large variations and the components in the conventional ringing-choke converter can be used unmodified. Ripple content of the DC output voltage shows a slight increase and is the subject for future research.
  • Keywords
    AC-DC power convertors; harmonic distortion; inductors; power capacitors; power conversion harmonics; power factor correction; power harmonic filters; rectifying circuits; television receivers; AC input current harmonics reduction; AC/DC converter; DC output voltage ripple content; active filter; capacitor-input-type rectifier; circuit configuration; class D equipment; high power factor; ringing choke converter-type switching regulator; television receiver; Active filters; Circuits; Costs; DC-DC power converters; Power system harmonics; Reactive power; Rectifiers; Regulators; TV receivers; Voltage;
  • fLanguage
    English
  • Journal_Title
    Industrial Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0046
  • Type

    jour

  • DOI
    10.1109/TIE.2003.809436
  • Filename
    1191811