Title :
An AC/DC converter with high power factor
Author :
Ochiai, Masashi ; Matsuo, Hirofumi
Author_Institution :
Digital Media Network Co., Toshiba Corp., Tokyo, Japan
fDate :
4/1/2003 12:00:00 AM
Abstract :
The television receiver often employs a capacitor-input-type rectifier. In this case, it is regulated as a class D piece of equipment. This paper presents a novel ringing-choke-converter-type switching regulator, which functions as an active filter. The proposed circuit features a simple circuit configuration and cost effectiveness. It achieves a high power factor of about 0.95 and reduces current harmonics (third, fifth, and seventh) in the AC input current to less than 40% of the limit value for class D. The voltage across the input smoothing capacitor does not show large variations and the components in the conventional ringing-choke converter can be used unmodified. Ripple content of the DC output voltage shows a slight increase and is the subject for future research.
Keywords :
AC-DC power convertors; harmonic distortion; inductors; power capacitors; power conversion harmonics; power factor correction; power harmonic filters; rectifying circuits; television receivers; AC input current harmonics reduction; AC/DC converter; DC output voltage ripple content; active filter; capacitor-input-type rectifier; circuit configuration; class D equipment; high power factor; ringing choke converter-type switching regulator; television receiver; Active filters; Circuits; Costs; DC-DC power converters; Power system harmonics; Reactive power; Rectifiers; Regulators; TV receivers; Voltage;
Journal_Title :
Industrial Electronics, IEEE Transactions on
DOI :
10.1109/TIE.2003.809436