• DocumentCode
    1173466
  • Title

    A new approach to the diagnosis of solid insulation systems based on PD signal inference

  • Author

    Cavallini, A. ; Montanari, G.C. ; Contin, A. ; Pulletti, F.

  • Author_Institution
    DIE-LIMAT, Bologna Univ., Italy
  • Volume
    19
  • Issue
    2
  • fYear
    2003
  • Firstpage
    23
  • Lastpage
    30
  • Abstract
    The authors have developed digital instrumentation that can measure the amplitude, shape, phase, and number of pulses per cycle. Examples are given of results obtained from an induction motor, a hydrogenerator, a polymeric cable system with a defective joint, and a high-voltage current transformer.
  • Keywords
    cable jointing; current transformers; digital instrumentation; hydroelectric generators; induction motors; insulation testing; machine insulation; partial discharge measurement; power cable insulation; power cable testing; signal detection; PD pulse signals detection; PD signal inference; basic defect characteristics identification; defective cable joint; digital instrumentation; high-voltage current transformer; hydrogenerator; induction motor; noise rejection; partial discharge measurement; polymeric cable system; pulses per cycle number measurement; signal separation; solid insulation systems diagnosis; Induction motors; Instruments; Phase measurement; Polymers; Power transformer insulation; Pulse measurements; Pulse shaping methods; Pulse transformers; Shape measurement; Solids;
  • fLanguage
    English
  • Journal_Title
    Electrical Insulation Magazine, IEEE
  • Publisher
    ieee
  • ISSN
    0883-7554
  • Type

    jour

  • DOI
    10.1109/MEI.2003.1192033
  • Filename
    1192033