DocumentCode :
1173691
Title :
Failure Analysis Of Synathetic Insulators With Fiberglass Rod Submitted To Mechanical Loads
Author :
Mier-Maza, R. ; Lanteigne, J. ; de Tourreil, C.
Author_Institution :
Hydro Quebec Institute of Research
Issue :
9
fYear :
1983
Firstpage :
3123
Lastpage :
3130
Abstract :
Four end fitting designs of long rod fiberglass core suspension insulators are studied and the failure mechanisms are analyzed after UTS and creep tests. The fracture occurs in the fiberglass rod due to the stresses induced by the metal part of the endfitting that hold the insulating components.
Keywords :
Creep; Failure analysis; Fitting; Glass; Insulation; Insulator testing; Optical fiber testing; Power transmission lines; Stress; Voltage;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1983.318119
Filename :
4112322
Link To Document :
بازگشت