DocumentCode :
1174247
Title :
Full-Scale Tests of TDD Antigalloping Devices (Torsional Damper and Detuner)
Author :
Lilien, J. L. ; Vinogradov, A.
Author_Institution :
University of Liege; ESSP
Volume :
21
Issue :
11
fYear :
2001
Firstpage :
61
Lastpage :
62
Abstract :
A new antigalloping device for overhead lines with bundle conductors was introduced ten years ago, after laboratory tests and observations on actual 400 kV lines [2],[4]. A systematic full-scale test was performed in Kazakhstan in order to better evaluate TDD efficiency. This report details the test station and the results obtained over a period of several months of testing and measurement. The tests were carried out thanks to the mutual efforts of the ESSP and the Kazakh Power Research Institute (KazNIIE) at the field tests stand located in Chokpar.
Keywords :
Artificial intelligence; Data compression; Discrete wavelet transforms; Filters; Power quality; Testing; Transmission line measurements; Voltage fluctuations; Wavelet analysis; Wavelet packets; Power transmission lines; measurement; test facilities; vibration control;
fLanguage :
English
Journal_Title :
Power Engineering Review, IEEE
Publisher :
ieee
ISSN :
0272-1724
Type :
jour
DOI :
10.1109/MPER.2001.4311179
Filename :
4311179
Link To Document :
بازگشت