• DocumentCode
    1174681
  • Title

    Eight-switch, three-phase rectifier for power factor correction

  • Author

    Lin, B.-R. ; Lee, Y.-C.

  • Author_Institution
    Dept. of Electr. Eng., Nat. Yunlin Univ. of Sci. & Technol., Taiwan
  • Volume
    151
  • Issue
    6
  • fYear
    2004
  • Firstpage
    666
  • Lastpage
    672
  • Abstract
    An eight-switch, three-phase neutral-point switch-clamped rectifier is presented in order to achieve a high input power factor and to draw sinusoidal currents from the AC mains. In the conventional three-phase, neutral-point switch-clamped rectifier, the circuit configuration consists of six power switches with voltage stress vdc and three AC power switches with voltage stress vdc/2. There are only four power switches with a voltage stress of the DC bus voltage and two AC power switches with a voltage stress of half the DC bus voltage in the proposed rectifier. The main functions of the proposed control scheme are to achieve unity input power factor, to draw sinusoidal line currents from the AC source, and to keep the DC link voltage constant. Analysis and a mathematical model of the proposed rectifier are derived. Some simulations and experimental results are provided in order to verify the effectiveness of the proposed control scheme.
  • Keywords
    mathematical analysis; power engineering computing; power factor correction; rectifying circuits; switching convertors; AC mains; AC power switches; DC bus voltage; DC link voltage; Matlab/Simulink software package; eight-switch, three-phase neutral-point switch-clamped rectifier; high input power factor; mathematical model; power factor correction; sinusoidal line currents; voltage stress;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings -
  • Publisher
    iet
  • ISSN
    1350-2352
  • Type

    jour

  • DOI
    10.1049/ip-epa:20040977
  • Filename
    1363613