Title :
Experimental Determination of Hydromechanical Constant Speed Drive Precise Frequency Control Accuracy
Author_Institution :
Project Engineer, Research Sundstrand Aviation, Division of Sundstrand Corporation, Rockford, Illinois
fDate :
7/1/1966 12:00:00 AM
Abstract :
The paper presents a discussion of the measured speed control accuracy of a Hydro-Mechanical constant speed drive with precise speed trim. The error between the generator output frequency and the precise reference oscillator frequency is measured during generating system operation representing a greatly accelerated flight schedule. The digital instrumentation used to measure the error was developed specifically for this test and is described. The tests were made possible by the availability of a Programmed Test Area (PTA) which allows the test conditions to be repeated accurately through the application of Digital Programming. The test results indicate that frequency control accuracy is essentially determined by the reference.
Keywords :
Acceleration; Flip-flops; Frequency control; Frequency measurement; Instruments; Oscillators; Pulse width modulation; Testing; Velocity control; Vibrations;
Journal_Title :
Aerospace and Electronic Systems, IEEE Transactions on
DOI :