DocumentCode :
1176401
Title :
Results from the SLD barrel CRID detector
Author :
Abe, K. ; Antilogus, P. ; Aston, D. ; Baird, K. ; Bean, A. ; Ben-David, R. ; Bienz, T. ; Bird, F. ; Caldwell, D.O. ; Cavalli-Sforza, M. ; Coller, J. ; Coyle, P. ; Coyne, D. ; Dasu, S. ; Dolinsky, S. ; D´Oliveira, A. ; Duboscq, J. ; Dunwoodie, W. ; Hallewe
Author_Institution :
Dept. of Phys., Tohoku Univ., Sendai, Japan
Volume :
41
Issue :
4
fYear :
1994
Firstpage :
862
Lastpage :
865
Abstract :
We report on operational experience with and experimental performance of the SLD barrel Cherenkov Ring Imaging Detector from the 1992 and 1993 physics runs. The liquid (C/sub 6/F/sub 14/) and gas (C/sub 5/F/sub 12/) radiator recirculation systems have performed well, and the drift gas supply system has operated successfully with TMAE for three years. Cherenkov rings have been observed from both the liquid and gas radiators. The number and angular resolution of Cherenkov photons have been measured, and found to be close to design specifications.<>
Keywords :
Cherenkov counters; CRID detector; Cherenkov Ring Imaging Detector; Cherenkov photons; SLD barrel; TMAE; angular resolution; drift gas supply system; gas radiator recirculation systems; liquid radiator recirculation systems; Astronomy; Computed tomography; Contracts; Detectors; Extraterrestrial measurements; Laboratories; Linear accelerators; Nuclear physics; Superluminescent diodes; USA Councils;