DocumentCode
1176749
Title
A Note on Fundamental Suppression in Harmonic Measurements
Author
Wagner, Herbert M.
Author_Institution
RCA Radiotron Company, Inc., Harrison, New Jersey
Volume
23
Issue
1
fYear
1935
Firstpage
85
Lastpage
88
Abstract
The measurement of the harmonic components of a periodic wave having a fundamental amplitude which predominates can sometimes be advantageously accomplished by using a network to suppress the fundamental component from the input terminals of the harmonic analyzing device. In this paper the method is discussed in connection with various harmonic analyzers and a few calculations are given to show the effectiveness of a bridge type of fundamental suppressing circuit.
Keywords
Bridge circuits; Circuit analysis; Cutoff frequency; Frequency measurement; Harmonic analysis; Harmonic distortion; Intelligent networks; Power harmonic filters; Transformers; Voltage;
fLanguage
English
Journal_Title
Radio Engineers, Proceedings of the Institute of
Publisher
ieee
ISSN
0731-5996
Type
jour
DOI
10.1109/JRPROC.1935.227241
Filename
1685756
Link To Document