Abstract
Two isotropic vector stop models are compared. One is a superposition of scalar stop models and the other uses a geometrically vectorized stop hysteron. Their simulated rotational hysteresis losses are adjusted to a measured loss. The latter adjusted vector stop model accurately represents the rotational hysteretic property.
Keywords
eddy current losses; magnetic hysteresis; magnetic leakage; geometrically vectorized stop hysteron; isotropic vector stop models; rotational hysteresis losses; Isotropic vector hysteresis; rotational hysteresis loss; silicon steel sheet; superposition; vector stop hysteron;