• DocumentCode
    1178116
  • Title

    Monitoring the Standard Frequency Emissions

  • Author

    Lapham, Evan G.

  • Author_Institution
    National Bureau of Standards, Washington, D.C.
  • Volume
    23
  • Issue
    7
  • fYear
    1935
  • fDate
    7/1/1935 12:00:00 AM
  • Firstpage
    719
  • Lastpage
    732
  • Abstract
    The method and equipment used in monitoring the standard frequency emissions are described in this paper. The emissions are continuously recorded in terms of the primary standard of frequency maintained by the Bureau of Standards. By means of selector circuits and frequency multipliers the received signal is heterodyned with the appropriate harmonic of the primary standard. The beat frequency is then recorded on a recording potentiometer by means of a circuit arrangement which produces a potential difference that is proportional to the frequency difference. The records show that the emissions have been in agreement with the primary frequency standard within two parts in one hundred million at practically all times, and the absolute value of the frequency transmitted is rarely in error by as much as one part in ten million.
  • Keywords
    Circuits; Frequency measurement; Helium; Laboratories; Monitoring; NIST; Oscillators; Potentiometers; Radio frequency; Radio transmitters;
  • fLanguage
    English
  • Journal_Title
    Radio Engineers, Proceedings of the Institute of
  • Publisher
    ieee
  • ISSN
    0731-5996
  • Type

    jour

  • DOI
    10.1109/JRPROC.1935.226412
  • Filename
    1685927