• DocumentCode
    1178748
  • Title

    Location of Small Discharges in Plastics Insulated High Voltage Cables

  • Author

    Wieringa, L.

  • Author_Institution
    NKF KABEL B. V. Power Cable Division High Voltage Research Laboratory
  • Issue
    1
  • fYear
    1985
  • Firstpage
    1
  • Lastpage
    8
  • Abstract
    This paper describes a non-destructive measuring method to locate small discharges in shielded plastics insulated high voltage cables. The sensitivity is so high that even discharges less than 5 pC can be located in long lengths of cable (> 1000 m).
  • Keywords
    Cable insulation; Conductors; Fault location; Laboratories; Plastic insulation; Power cables; Power measurement; Pulse measurements; Transactions Committee; Voltage;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1985.318850
  • Filename
    4112894