Title :
Hearing impairment simulator based on compressive gammachirp filter
Author :
Nagae, Misaki ; Irino, Toshio ; Nisimura, Ryuich ; Kawahara, Hideki ; Patterson, Roy D.
Author_Institution :
Fac. of Syst. Eng., Wakayama Univ., Wakayama, Japan
Abstract :
This paper describes a simulator for presenting normal hearing (NH) listeners with the experience of a hearing impaired (HI) listener. The simulator is based on the compressive gammachirp (cGC) filter used to derive level-dependent filter shapes and the cochlear compression function from to notched-noise masking data. The level dependence of the cGC is reversed to produce inverse compression which is used to resynthesize sounds that cancel the compression applied by the auditory system of the NH listener. A frame-based analysis/synthesis procedure is newly introduced to improve processing speed for a graphical user interface (GUI) that allows the users to control the degree of compression within the range of the audiogram of the HI person. The simulator is intended for speech-language-hearing therapists (ST) and patients´ families.
Keywords :
cochlear implants; graphical user interfaces; medical signal processing; GUI; auditory system; cochlear compression function; compressive gammachirp filter; frame-based analysis procedure; frame-based synthesis procedure; graphical user interface; hearing impaired listener; hearing impairment simulator; inverse compression; level-dependent filter shape; normal hearing listener; notched-noise masking data; speech-language-hearing therapist; Auditory system; Frequency measurement; Gain; Graphical user interfaces; Noise; Shape;
Conference_Titel :
Asia-Pacific Signal and Information Processing Association, 2014 Annual Summit and Conference (APSIPA)
Conference_Location :
Siem Reap
DOI :
10.1109/APSIPA.2014.7041579