DocumentCode :
1181633
Title :
Young´s Modulus Reconstruction for Radio-Frequency Ablation Electrode-Induced Displacement Fields: A Feasibility Study
Author :
Jiang, Jingfeng ; Varghese, Tomy ; Brace, Christopher L. ; Madsen, Ernest L. ; Hall, Timothy J. ; Bharat, Shyam ; Hobson, Maritza A. ; Zagzebski, James A. ; Lee, Fred T., Jr.
Author_Institution :
Med. Phys. Dept., Univ. of Wisconsin, Madison, WI, USA
Volume :
28
Issue :
8
fYear :
2009
Firstpage :
1325
Lastpage :
1334
Abstract :
Radio-frequency (RF) ablation is a minimally invasive treatment for tumors in various abdominal organs. It is effective if good tumor localization and intraprocedural monitoring can be done. In this paper, we investigate the feasibility of using an ultrasound-based Young´s modulus reconstruction algorithm to image an ablated region whose stiffness is elevated due to tissue coagulation. To obtain controllable tissue deformations for abdominal organs during and/or intermediately after the RF ablation, the proposed modulus imaging method is specifically designed for using tissue deformation fields induced by the RF electrode. We have developed a new scheme under which the reconstruction problem is simplified to a 2-D problem. Based on this scheme, an iterative Young´s modulus reconstruction technique with edge-preserving regularization was developed to estimate the Young´s modulus distribution. The method was tested in experiments using a tissue-mimicking phantom and on ex vivo bovine liver tissues. Our preliminary results suggest that high contrast modulus images can be successfully reconstructed. In both experiments, the geometries of the reconstructed modulus images of thermal ablation zones match well with the phantom design and the gross pathology image, respectively.
Keywords :
Young´s modulus; biomechanics; biomedical electrodes; biomedical ultrasonics; cancer; deformation; edge detection; hyperthermia; image reconstruction; iterative methods; liver; medical image processing; phantoms; surgery; tumours; Young´s modulus reconstruction; abdominal organ; bovine liver tissue; edge-preserving regularization; electrode-induced displacement field; intraprocedural monitoring; medical ultrasound; radio-frequency ablation; thermal ablation zones match; tissue coagulation; tissue deformation; tissue-mimicking phantom; tumors treatment; Abdomen; Coagulation; Image reconstruction; Imaging phantoms; Minimally invasive surgery; Monitoring; Neoplasms; Radio frequency; Reconstruction algorithms; Ultrasonic imaging; Ablation; ablative therapy; elastic modulus imaging; elasticity imaging; elastography; inverse problem; Algorithms; Animals; Catheter Ablation; Cattle; Elastic Modulus; Elasticity Imaging Techniques; Finite Element Analysis; Image Processing, Computer-Assisted; Liver; Phantoms, Imaging; Radio Waves;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2009.2015355
Filename :
4796317
Link To Document :
بازگشت