• DocumentCode
    1181753
  • Title

    Chirp imaging vibro-acoustography for removing the ultrasound standing wave artifact

  • Author

    Mitri, F.G. ; Greenleaf, J.F. ; Fatemi, M.

  • Author_Institution
    Dept. of Physiol. & Biomed. Eng., Ultrasound Res. Lab., Rochester, MN, USA
  • Volume
    24
  • Issue
    10
  • fYear
    2005
  • Firstpage
    1249
  • Lastpage
    1255
  • Abstract
    Vibro-acoustography (VA) is an imaging technique that uses the dynamic (oscillatory) radiation force of two continuous-wave (CW) ultrasound to image objects at low frequency (within the kHz range). In this technique, the dynamic radiation force is created by means of a confocused transducer emitting two ultrasound beams at slightly-shifted frequencies f1 and f2=f1+Δf. It has been demonstrated previously that high-resolution images of various types of inclusions and tissues can be obtained using this technique. However, if the targeted object reflects ultrasound directly back to the transducer, standing waves are produced that result in an artifact in the VA image. The goal of this study is to remove the standing wave artifact and improve VA images by means of a new process called chirp imaging. The procedure consists of sweeping the frequencies of the primary ultrasound beams in a selected bandwidth while keeping Δf constant during the sweep. The chirp image is produced by averaging the amplitude of the acoustic emission produced during the sweep. Vibro-acoustography chirp imaging experiments are performed on a stainless-steel sphere attached to a latex sheet in a tank of degassed water. The resulting chirp images demonstrate remarkable reduction of the standing wave artifact compared to the "fixed frequency" VA images.
  • Keywords
    biological tissues; biomechanics; biomedical ultrasonics; ultrasonic transducers; biological tissues; chirp imaging vibro-acoustography; confocused transducer; continuous wave ultrasound; dynamic radiation force; stainless steel sphere; ultrasound standing wave artifact removal; Acoustic beams; Acoustic emission; Acoustic imaging; Acoustic signal detection; Biomedical engineering; Chirp; Frequency estimation; Mechanical factors; Physiology; Ultrasonic imaging; Acoustic emission; chirp imaging; dynamic radiation force; standing wave; ultrasound imaging; vibro-acoustography; Acoustics; Algorithms; Artifacts; Image Enhancement; Image Interpretation, Computer-Assisted; Imaging, Three-Dimensional; Phantoms, Imaging; Reproducibility of Results; Sensitivity and Specificity; Tomography; Ultrasonography; Vibration;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2005.854518
  • Filename
    1514545